Blanc On-off DM16-01.01.07en
42 Service manual
T1-Ts
High
Low
Medium
10.4.2.4 Low evaporator coil temperature T2 protection
T2
On
Off
When the evaporator coil temp.T2 keeps lower than setting value, the compressor and outdoor fan will
shut off.
10.4.2.5 High condenser temperature T3 protection
(only for MSMAD-24HRN1-QB8W)
T3
Compressor Off
Compressor On
When high condenser temp. T3 is more than setting value, the compressor will stop.
During the protection, the outdoor fan keeps working.