EasyManuals Logo

Midea MSMA1C-18HRN1 User Manual

Midea MSMA1C-18HRN1
59 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #54 background imageLoading...
Page #54 background image
Blanc On-off DM16-01.01.07en
54 Service manual
11.2.5 Open circuit or short circuit of temperature sensor diagnosis and solution (E4)
Error Code
E4/E5/F2
Malfunction decision
conditions
If the sampling voltage is lower than 0.06V or higher than 4.94V,
the LED will display the failure.
Supposed causes Wiring mistake
Sensor faulty
PCB faulty
Trouble shooting:

Questions and Answers: