EasyManua.ls Logo

Midea MSR1-12HRN1-QC2 User Manual

Midea MSR1-12HRN1-QC2
63 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
RSEU-A1-1206
SERVICE MANUAL
MIDEA AIRCONDITIONER
EUROPE MARKET
SPLIT WALL-MOUNTED TYPE
R ON-OFF SERIES

Questions and Answers:

Midea MSR1-12HRN1-QC2 Specifications

General IconGeneral
BrandMidea
ModelMSR1-12HRN1-QC2
CategoryAir Conditioner
LanguageEnglish

Summary

Precaution

Safety Precaution

General safety instructions to prevent injury and property damage.

Warning

Specific warnings related to installation, electrical work, and product handling.

Cautionary Notes

Important cautionary advice for installation and operation.

Functionality Overview

Model Names of Indoor/Outdoor Units

Lists indoor and outdoor unit model names by series and capacity.

Dimensional Specifications

Indoor Unit Dimensions

Details the dimensions (W, H, D) for various indoor unit models.

Outdoor Unit Dimensions

Provides dimensions and clearance specifications for outdoor units.

Refrigerant System Diagrams

Cooling Only Models Refrigerant Cycle

Illustrates the refrigerant flow for cooling-only air conditioners.

Heat Pump Models Refrigerant Cycle

Diagrams the refrigerant flow for heat pump models, including heating.

Wiring Diagrams

Indoor Unit Wiring

Detailed wiring diagrams for various indoor unit models.

Outdoor Unit Wiring

Wiring diagrams illustrating connections for outdoor units.

Installation Procedures

Wrench Torque for Installation

Specifies torque values for pipe connections during installation.

Cable Connection Guidelines

Recommendations for selecting power cords based on appliance current.

Pipe Length and Elevation

Details pipe length limits and refrigerant amount adjustments.

First-Time Installation: Vacuum Pump

Step-by-step guide for air purging using a vacuum pump.

First-Time Installation: Refrigerant Purge

Procedure for purging air with refrigerant during initial installation.

Adding Refrigerant for Long Pipes

Instructions for adding refrigerant when pipe length exceeds 5m.

Adding Refrigerant After Years of Use

Procedure for adding refrigerant to systems after extended operation.

Re-installation: Indoor Unit Repair

Steps for collecting refrigerant before indoor unit repair.

Re-installation: Indoor Unit Refrigerant Purge

Purging refrigerant after re-installation of the indoor unit.

Re-installation: System Evacuation

Procedure for evacuating the entire system during outdoor unit repair.

Re-installation: Refrigerant Charging

Process for charging refrigerant after outdoor unit re-installation.

Operation Characteristics and Functions

Operating Temperature Ranges

Lists temperature limits for cooling, heating, and drying modes.

Operational Cautions

Important notes regarding operating conditions and potential issues.

Abbreviated Technical Terms

Defines technical abbreviations used in the manual.

Indoor Display Functionality

Explanation of icons and indicators on the indoor unit display.

Main Protection Mechanisms

Details various protection features like time delay and current protection.

Operation Modes and Fan Control

Describes fan modes, compressor rules, and outdoor/indoor fan operation.

Evaporator and Condenser Temperature Protection

Protection functions related to evaporator and condenser temperatures.

Heating Mode Compressor and Fan Rules

Rules governing compressor and fan operation during heating.

Indoor Fan Operation in Heating

Indoor fan running rules specific to heating mode.

Anti-Cold Wind and Auto Fan Functions

Explanation of anti-cold wind feature and auto fan logic.

Defrosting Mode Conditions and Actions

Details conditions for entering and exiting defrosting mode.

Specific Defrosting Conditions

Defrosting conditions tailored for different model series.

Defrosting Sequence and Auto Mode

Visual guide to defrosting actions and auto mode operation.

Drying Mode Operation

Describes the operation and rules for the drying mode.

Forced Operation and Timer Functions

Details on forced operation modes and timer settings.

Sleep Mode and Auto-Restart

Explanation of sleep mode features and auto-restart function.

Troubleshooting Guide

Indoor Unit Error Displays

Lists error codes and associated failures for indoor units.

Fan Speed Out of Control Diagnosis

Diagnostic steps for troubleshooting indoor fan speed issues.

Temperature Sensor Error Diagnosis

Troubleshooting steps for open/short circuits in temperature sensors.

Over Current Protection Diagnosis

Diagnostic procedures for over current protection faults.

EEPROM Parameter Error Diagnosis

Troubleshooting steps for EEPROM parameter errors.

Zero Crossing Detection Error Diagnosis

Diagnostic process for zero crossing detection errors.

Communication Error Diagnosis

Troubleshooting for indoor/outdoor unit communication errors.

Related product manuals