19
Unit undersized
Determine if the unit is properly sized for the area to be cooled
or heated.
Condenser and Evaporator
Clean or replace if restricted.
shaded pole motor failure
Check and replace if the motor is failure.
Fan motor
Check the fan capacitor and replace if not within +/-10% of
manufactures rating.
Air flow
Clean or remove if any barrier is found to block the inlet/outlet
wind flow of the unit.
Less refrigerant
Check the tubes for reasons of leakage. Recycle the
refrigerant, correct the leakage points and recharge.
Capillary tube
Regulate the flow if capillary tube and make the evaporating
temperature appropriate if the evaporator is frosted. Replace if
blocked. Repair joint if leaking.
Compressor
The inlet and outlet valve of the compressor is damaged,
making the low pressure connected with the high pressure.
The refrigerating system can not produce high pressure and
low pressure. Replace the compressor after checking for the
reason.
Heat sources
Reduce if too many.
No cooling or
heating.
No power
Check the voltage. Call an electrician if no within the limit.
Wiring
Check the terminals. Repair and correct if loose.
Temperature setting
Check and adjust the temperature setting.
Mode setting
Check and adjust the mode setting.
Compressor
Check and replace if the compressor, the over-load protector
or wiring is broken.
Electric heater failure
Check and replace if the heater is damaged.
Over heat fuse failure
Check and replace if the fuse is damaged.
Main PCB
Check the voltage of main PCB. Replace the main PCB when
the unit failure in heating mode.
The unit starts and
stops frequently.
Power supply
The input power supply voltage is too low. Call an electrician if
not within limits.
Main PCB
Check and replace the main PCB if the compressor relay on
PCB is shorted or damaged.
Room temperature
When the room temperature is too high, the compressor will
protect.
Exploded View & Parts Listing: MPN-10CRN1-BH9

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Midea N series and is the answer not in the manual?

Midea N series Specifications

General IconGeneral
BrandMidea
ModelN series
CategoryAir Conditioner
LanguageEnglish

Related product manuals