28
8. Electronic function
8.1 Abbreviation
T1: Indoor ambient temperature
T2: Coil temperature of indoor heat exchanger
8.2 Display function
8.2.1 Icon explanation on indoor display board.
One of the following figures matches its display board.
Run indicator
Flash at 0.5Hz when the unit is standby. Illuminate when the unit is turned on.
Timer indicator
This indicator illuminates when TIMER is set ON/OFF.
Defrost Indicator
This indicator illuminates when the air conditioner starts defrosting
automatically or when the warm air control feature is activated in heating mode
Temperature indicator
Displays the temperature settings when the air conditioner is operational. Displays
the malfunction code.