EasyManua.ls Logo

Midea ODMFI-E-2110 - Page 170

Midea ODMFI-E-2110
179 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
170
CN8: Discharge temperature sensor
(2p,white)
CN12Heatsink temperature
sensor(2p,red)
CN9:T3/T4 temperature sensor
(2p/2p,white)
CN11:T2B-A,B,C,D,E temperature
sensor (2p/2p/2p/2p/2p,white)
CN15/CN23/CN26/CN30/CN33:
Electronic expansion valve
(6p/6p/6p/6p/6p,red)
CN37/CN29/CN21/CN16/CN13: S-
A,S-B,S-C,S-D,S-E
(3p/3p/3p/3p/3p,white)
CN10: High and low pressure switch
(2p/2p, white)
Wires:
CN17/CN18: 4-way valve (blue-blue)
CN19/CN20: connected to crankcase
heating cable. (black-red)
CN24/CN25: Electric heater of
chassis (orange-orange)
CN1:L-IN (red)
CN3:N-IN (black)
6) Disconnect the
grounding wire (yellow-green)
after removing the big handle.
7) Remove the PCB board.
CN17/CN18
CN19/CN20
CN24/CN25
CN13
CN16
CN21
CN29
CN37
CN30/CN23/CN33/CN26/CN15
CN8 CN12
CN9 CN11
CN10
CN3
CN1

Related product manuals