The difference between current limit
and shutdown current
Cooling T4≥50℃ current limit value
Cooling 49>T4≥45℃ current limit
value
Cooling 44>T4≥41℃ current limit
value
Cooling 40﹥T4≥33℃ current limit
value
Cooling 32>T4℃current limit value
Cooling stop protection current value
Heating mode:
For other models,
HeatT4Zone4I
HeatT4Zone3I
HeatT4Zone2I
HeatT4Zone1I
15
14
10
9
6
5
T4/°C
The difference between current
limit
Heating T4≥15℃current limit
value
Heating 14℃>T4≥10℃
current limit value
Heating 9℃>T4≥6℃ current
limit value
Heating 5℃>T4 current limit
value
Heating stop protection current
value
For M4OI-36HFN1-M, M5OG-48HFN1-M, M5OG-
48HFN1-M-[X],
HeatT4Zone4I
HeatT4Zone3I
HeatT4Zone2I
HeatT4Zone1I
15
14
10
9
6
5
T4/°C
HeatT4Zone0I
HeatT4Zone-1I
-4
-5
-9
-10
The difference between current
limit
and shutdown current
Heating T4≥15℃current limit
value
Heating 14℃>T4≥10℃
current limit value
Heating 9℃>T4≥6℃ current
limit value
Heating 5℃>T4≥-4℃ current
limit value
Heating -5℃>T4≥-9℃ current
limit value
℃ CoolT4Zone5I
50
49
45 CoolT4Zone4I
44
41
40 CoolT4Zone3I
33
32
CoolT4Zone2I
32
CoolT4Zone1I