22
Frequency (Hz)
0
COO
L_F1
COO
L_F2
COOL
_F24
COO
L_F2
5
Amendatory
capacity
demand.
0
1
2
24
25
The maximum running frequency is adjusted
according to the outdoor ambient temperature
55
54
Fmax= T4FREMAXC0
51.5
50.5 Fmax= T4FREMAXC1
45.5
44.5 Fmax= T4FREMAXC2
39
38 Fmax= T4FREMAXC3
33
32 Fmax= T4FREMAXC4
30
29 Fmax= T4FREMAXC5
22
20 Fmax= T4FREMAXC6
10
8 Fmax= T4FREMAXC7
0
-2 Fmax= T4FREMAXC8
-10
-12 Fmax= T4FREMAXC9
Fmax= T4FREMAXC10
Heating Mode
T1 Ts
4
0
a
3
1
-1
3
1
2
0
b
c
d
e
f
2
Capacity area
a
b
c
d
e
f
Norm code (N)
3
2
1.5
1
0.5
0
Model
9K
12K
18K
24K
HP
1.0
1.2
1.5
2.5
Note: The final result is an integer.
Then modify it according to a T2 average
(correction):
Note:Average value of T2Sum T2 value of all
indoor units)/ (indoor units number
T2 average
Decrease frequency
47
Keep frequency
40
Increase frequency
Use the following table and final capacity
request to confirm the operating frequency.
Frequency (Hz)
0
HEAT
_F1
HEAT
_F2
HEAT
_F24
HEAT
_F25
Amendatory
capacity
demand.
0
1
2
24
25
The maximum running frequency is adjusted
according to the outdoor ambient temperature