F indoor unit capacity demand code
F indoor unit evaporator outlet temperature (T
2B
F)
F indoor unit room temperature (T
1
F)
F indoor unit evaporator temperature (T
2
F)
EXV open angle for F indoor unit
EVI valve target angle(only for M5OG-
48HFN1-M-[X])
Actual data/4.
If the value is higher than 99, the digital display tube will show
single digit and tens digit.
For example, the digital display tube show “2.0”,it means the EXV
open angle is 120×4=480p.)
EVI valve open angle(only for M5OG-
48HFN1-M-[X])
EVI valve angle(only for M5OG-48HFN1-M-
[X])
Displays running frequency, running state, or malfunction code
Quantity of indoor units with working connection
Outdoor unit running mode code
Off: 0,Fan only: 1, Cooling: 2, Heating: 3, Forced cooling: 4. Forced
defrost:A
The capacity unit is horse power. If the indoor unit is not connected, the
digital display shows the following: “――”
(9K:1HP,12K:1.2HP,18K:1.5HP,24K:2.0HP)