12.2 Enabling/Disabling Mode and Setting Temperature
Both heat mode and DHW mode can be enabled and disabled through the wired controller
12.2.1 Heat Mode
There are two control methods for the heat mode:
• Water outlet temperature control
• Room temperature control
In water outlet temperature control mode, the hydraulic module operates according to the defined water outlet temperature
so that the water outlet temperature reaches the defined desired water outlet temperature. The water outlet temperature
can be set manually, or through the timer function and weather temperature curve.
• Steps for setting the water outlet temperature control mode of the hydraulic module: MENU > FOR SERVICEMAN >
HEAT MODE > LEAVING WATER TEMP..
• Set LEAVING WATER TEMP. to YES.
• The water outlet temperature ranges from 25°C to 80°C.
• Sets the mode to water outlet temperature control and heating main interface to MAIN.
Notes:
If LEAVING WATER TEMP. is set to YES, ROOM TEMP. is automatically set to NON. If ROOM TEMP. is set to YES, LEAVING
WATER TEMP. is automatically set to NON
Notes:
If LEAVING WATER TEMP. is set to YES, ROOM TEMP. is automatically set to NON. If ROOM TEMP. is set to YES, LEAVING
WATER TEMP. is automatically set to NON