Room Temperature Control
In room temperature control mode, set the desired room temperature. The hydraulic module will control the operating of the
hydraulic module according to the room temperature collected by the wired controller. The desired room temperature can be
set manually, or through the timer function and weather temperature curve.
• Take the following steps to set room temperature control mode: MENU > FOR SERVICEMAN > HEAT MODE > ROOM
TEMP..
• Set ROOM TEMP. to YES.
• Room temperature ranges from 17 C to 30 C.
• Sets the mode to water outlet temperature control and heating main interface to ROOM.
Notes:
1. The wired controller should be installed where heating is needed.
2. If LEAVING WATER TEMP. is set to YES, ROOM TEMP. is automatically set to NON. If ROOM TEMP. is set to YES,
LEAVING WATER TEMP. is automatically set to NON.