Here is an abbreviated “Cheat Sheet” from NCI
PRIME
1. BLANK
DISTANCE 2. FT. Covered After 5280 FT. Switch to MILE
IMPLEMENT WIDTH
3. Boom Switch Box OFF 0
Boom Switch ON Swath in FEET
Must set Flow Control (LIQ) AUTO RANGE HOLD
See Note (2) (DRY) HYD. VALVE CLOSED
TOTAL APPLIED 4. 0 to Start Total LBS/AC AppliedSpread
APPLICATION RATE
5. Desired LBS/AC will oscillate
% RATE 6. 100 ALWAYS, if other than 100 change Target Rate LBS/AC
PRODUCT VOLUME
7. Enter full capacity from Constant in Set Up (GC). Weight to match ma-
terial in unit. Then number shows how much material remains in unit.
Beeps at 10% of entered weight. See Note (3)
TOTAL AREA 8. 0 to start May require special instruction
DO NOT ZERO OUT UNTIL END OF DAY or INTERVAL OF CHOICE
FIELD AREA 9. 0 to start Change Finish Job
SPEED 10. MPH travel 0 is still
SCAN 11. Totals and setting of some selector functions
TEST SPEED 12. 10 MPH Blinks during testing only
PRIME
A. C Stnd
DISTANCE
B. Calibration Number See Note (1) This must be checked
IMPLEMENT WIDTH
C. Swath in inches 50’ = 600‖; 60’ = 720‖
Lock in position with conveyor interface master on (Number 1 lit
with single switch is dry swath)
*Must fill out all Slots 2—9 with a value ―0‖
TOTAL APPLIED
D. Spreader Constant must match gate height for unit
GET OUT of the truck and check!
APPLICATION RATE
E. Must match density in LBS/CU FT
% RATE F. 10% Change rate by increments of + or - 10%
PRODUCT VOLUME G. LBS Enter as constant 12’ Body = 14000 lb / 10’ Body = 12000 lb
TOTAL AREA H. ERR
FIELD AREA I. ―0‖ - Enter acre to hear audible alarm
SPEED J. Set GSO to ―0‖ on dry—ALWAYS
SCAN K. ERR
TEST SPEED L. 10 MPH Steady suggested for testing
OPERATE
SET UP
Under Set Up most displays blink.
NOTES
(1) Radar constant will vary with radar type: Mid-Tech Compact Radar - Start at 780 or DickeyJohn Radar - Start at 1000
(2) Check Valve SettingDryClosed
(3) Enter by constant in setup. (G) To go to a higher number, must go down then back up.
Highlighted Items MUST be performed at the beginning of each job. All other fields
are for information and should be reset at your discretion.