Cleaning and care
31
Lift the panel into the deflector plate
and hook it in at the back.
T
ilt the panel upwards at the front
and press it into the locking clip.
Resetting the grease filter operating
hou
rs counter
After cleaning, the operating hours
coun
ter needs to be re-set.
Whilst the fan is switched on, pr
ess
the operating hours control  for
approx. 3 seconds, until only the 1 is
flashing.
The grease filter symbol goes out.
If you want to clean the grease filter(s)
befor
e the operating hours counter has
reached its maximum,
P
ress the operating hours control
 for approx. 6 seconds, until only
the 1 is flashing.