Technical data
Rated load
DA 361, DA 371 . . . . . . . . . . . . . 238 W
Lighting . . . . . . . . . . . . . . . . . 1 x 18 W
Voltage (UK, IRL) . . . . . . . . . . AC 230 V
Frequency . . . . . . . . . . . . . . . . ~ 50 Hz
Fuse rating (UK). . . . . . . . . . . . . . . 13 A
Fuse rating (IRL) . . . . . . . . . . . . . . 10 A
Fan power
Extraction power according to
EN 61591
Extraction system ø 125 mm:
Level I. . . . . . . . . . . . . . . . . . . 220 m
3
/h
Level II . . . . . . . . . . . . . . . . . . 350 m
3
/h
Level III. . . . . . . . . . . . . . . . . . 450 m
3
/h
Intensive level. . . . . . . . . . . . . 560 m
3
/h
Extraction system ø 100 mm:
Level I. . . . . . . . . . . . . . . . . . . 200 m
3
/h
Level II . . . . . . . . . . . . . . . . . . 330 m
3
/h
Level III. . . . . . . . . . . . . . . . . . 380 m
3
/h
Intensive level. . . . . . . . . . . . . 440 m
3
/h
Unrestricted . . . . . . . . . . . . . . 650 m
3
/h
Recirculation with charcoal filters:
Level I. . . . . . . . . . . . . . . . . . 160 m
3
/h*
Level II . . . . . . . . . . . . . . . . . 240 m
3
/h*
Level III. . . . . . . . . . . . . . . . . 300 m
3
/h*
Intensive level. . . . . . . . . . . . 360 m
3
/h*
*Depending on installation.