EasyManua.ls Logo

Miele G 5000 SC ACTIVE - Checking the Filters in the Wash Cabinet; Cleaning the Filters

Miele G 5000 SC ACTIVE
96 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cleaning and care
72
Checking the filters in the
wash cabinet
The filter combination in the base of the
wash cabinet retains coarse soiling
from the suds solution. This prevents
soiling getting into the circulation
system and re-entering the wash
cabinet through the spray arms.
Damage due to soiling entering
the circulation system.
Without filters, soiling can enter the
circulation system and cause a
blockage.
Do not run a wash programme
without the lower spray arm or
without the filters fitted.
When cleaning the filters and spray
arms, make sure that coarse soiling
cannot get into the circulation
system.
The filters can become clogged by
soiling that collects over time. The level
of soiling and the time it takes before
the filters need cleaning will vary
depending on use.
Monitor the condition of the filter
combination regularly and clean it if
necessary.
Cleaning the filters
Switch the dishwasher off.
Remove the lower spray arm (see
“Cleaning and care - Cleaning the
spray arms”).
Before removing the filter
combination, remove any coarse
soiling to prevent it from entering the
circulation system.
Remove the filter combination.

Table of Contents