Problem solving guide
73
Water inlet fault
Problem Cause and remedy
The In-operation indic-
ator is flashing quickly.
The buzzer is sounding.
One of the following
faults is shown in the
display:
Open stopcock The stopcock is closed.
Open the stopcock fully.
Water intake Before rectifying the problem:
Switch the dishwasher off with the button.
The water intake is restricted.
Open the stopcock fully and start the programme
again.
Clean the water inlet filter (see "Maintenance").
The water pressure at the intake is lower than
50kPa (0.5bar).
Seek professional advice.
The following message
appears in the display
during the SolarSave pro-
gramme:
Intake temp. low
The intake water has not reached the required tem-
perature of 45°C (see "Plumbing, Connection to the
water supply").
Start the programme again.
If the fault message appears again, select a differ-
ent programme.