EasyManua.ls Logo

Miele G 7883 CD - Drainage System Connection

Miele G 7883 CD
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Drainage
^
The drainage system is fitted with a
non-return valve which prevents dirty
water from flowing back into the
machine via the drain hose.
^
The machine should preferably be
connected to a separate drainage
system onsite.
If separate drainage is not available
contact Miele Technical Service for
advice.
The onsite drain connection point
should be located between 1 ft.
(0.3 m) and 3 ft. (1 m) above the
lower edge of the machine.
If it is lower than 1 ft. (0.3 m), lay the
hose in a curve at a height of at least
1 ft. (0.3 m).
The drainage system must be able to
take a minimum drainage flow of
16 l/min.
^ The drain hose is approx. 5 ft.
(1.5 m), is flexible and has an internal
diameter of
7
/
8
in. (22 mm). It must
not be shortened. Hose clamps are
supplied for securing it in position.
^
A longer drain hose (up to 13 ft.
[4 m]) is available to order from
Miele.
^
The drainage system must not
exceed 13 ft. (4 meters).
^
See the supplied installation diagram.
Plumbing
72