KM 406
When converting to liquid gas, the
main jets and the small jets of all
burners must be changed.
Nominal rating at high setting
Gas type MJ/h
Burner NG
ULPG
17.60
17.40
Nominal rating at low setting
Gas type MJ/h
Burner NG
ULPG
0.65
0.72
Screw in the new jets according to the
following table.
Jet table
For AUS and NZ
Main jet
Ø
Low setting
jet Ø
NG 2.0 0.90 / 0.40
Nr. 34
ULPG 1.12 0.52 / 0.23
Nr. 7
The jet markings refer to 1/100 mm of
the jet orifice.
Conversion to another type of gas