The dryer must be disconnected from
the gas supply piping system during any
pressure testing of that system at test
pressures in excess of ½ psi (3.45 kPa).
The dryer must be isolated from the gas
supply piping system by closing the
equipment shut-off valve during any
pressure testing of the gas supply piping
system at test pressures equal to or less
than
1
/
2
psi (3.45 kPa).
Adequate clearances shall be provided
for air openings into the combustion
chamber.
Provide adequate clearances from
combustible construction.
A
1
/
8
inch NPT minimum plugged
tapping, accessible for test gage
connection, must be installed immediately
upstream of the gas supply connection to
the dryer.
A vent line must be installed from the
regulator vent to the outdoors (if
applicable).
Do not install or store the machine where
it is exposed to weather.