Loading...
M
Water intake fault
Call the Miele Service Department.
if restart is without success.
if
^
Check the water supply and press h
"Start".
§
Heating system fault
Program Stop
Press Start.
if
^
Press h "Start" to continue the program
without heating.
If the program has a "Thermostop" the
program will time out.
^ Call Miele Technical Service.
^ Some programs may be canceled if this
messages shows.
Call Technical Service.
m
Motor system error
Program stop. Press Start.
Motor temperature too high.
if
^
Allow the motor to cool.
§
Imbalance fault
Call the Miele Service Department
if restart is without success.
i A
Large imbalance, the imbalance switch has
activated.
^
Turn the machine off and on again
^
Press h "Start".
q
Drain error
Call the Miele Service Department
if restart is without success.
if
^
Check and clean the drain system and
press h "Start".
A defective drain valve should only be
replaced by an authorized service
technician.
ö
Dispensing system fault
Fill dispensing container 1
Press Start.
if
^
Change/fill the dispensing container.
§
Card error
Reinsert card correctly in card reader.
Continue: Press Start.
if
^ Insert the card properly into the card
reader.