Miele S 8360 Specifications

General IconGeneral
Power1200 W
Dustbag Capacity4.5 l
Weight5.4 kg
Cord Length7.5 m
Wattage1200 W
Power Consumption1200 W
Noise Level77 dB
Filter TypeAirClean filter
Filter SystemAirClean filter

Summary

Warning and Safety Instructions

General Safety Information

All repairs should be performed by a trained technician in strict accordance with national, state and local codes.

010 Base Unit

Caster (Dynamic Drive) Removal

Using a flathead screwdriver, lever the wheel out of the caster, then lever the caster out of the base.

Lighting Assembly Replacement (Uniq Only)

Remove the bumper strip (010 Fig. 2, Pos. 2) and T20 screws securing parking slots.

020 Cover Frame

Cover Frame Removal

Remove the bag holder, seal, exhaust filter, and four T20 screws securing the cover frame.

030 Dust Compartment Lid

Dust Channel Assembly Removal

Remove four T20 screws securing the dust channel assembly. Release hinge socket from retainers.

040 Operating Unit

Motor Does Not React in Auto Setting

Troubleshooting for motor issues in automatic setting, including clogged channels and kinked hoses.

050 Motor, Cord Reel

Suction Power Too Low

Troubleshooting for low suction power due to clogged nozzle/hose, full dustbag, or clogged filters.

Motor Does Not Run

Troubleshooting for motor not running due to jammed park switch, defective winding, or tripped thermal protection.

060 Suction Hose, Handle (S 83xx)

LEDs in LED Handle Do Not Light

Troubleshooting for LEDs not lighting up in the handle, caused by dead batteries.

061 Radio-Controlled Suction Hose (S 87xx)

Radio-Controlled Handle Not Functioning

Troubleshooting for the radio-controlled handle not functioning, typically due to a dead battery.