External drainage of condensed water
The condensed water can be drained
off directly if the machine is installed
near a sink, drain outlet, etc.
Accessories supplied:
- 2 m drain hose
- Hose clamp
- Rubber connection sleeve
- Hose clip
Installation:
Detach the hose clip from the drain
outlet at the back of the machine
and remove the rubber plug.
Push the drain hose onto the drain
outlet. Make sure that the hose is
firmly secured by the clip and not
kinked.
Max. drain hose length: 3.0 m
Max. delivery head: 1.0 m