Cleaning the condenser unit
Detergent residue, hair and fine fluff
from the dryer can get through the fluff
filters and block the condenser unit.
Dust from the room in which the dryer is
installed can also get into the
condenser unit and cause a blockage.
Check the condenser unit at least
once a year. Always check it if the
Clean out airways message
appears. Clean it if necessary.
Removing the condenser unit
^
Open the service panel. Hold the
panel securely when doing this.
^
Now remove the panel by pulling it
diagonally upwards and place it to
one side.
^
Turn the lever on the inner cover
downwards to the vertical position.
^ Tilt the cover forwards.
^ Remove it by pulling it diagonally
upwards.
^
Turn the lever on the condenser unit
upwards to the vertical position.