Description of the machine
Programme sequence / check lights
Fault messages
Programme sequence or check lights come
on or flash to indicate a fault or interruption.
The "Gas heating" indicator light goes out on
dryers with gas heating.
The messages are:
Heating
Fault in the heating system.
Action: Please inform the Service department
Safety period
The maximum running time of the drying pro-
gramme was exceeded because the residual
moisture at the start of the programme was
too high.
Action: Where the residual moisture was too
high start the drying programme again.
If the fault message occurs again please call
the Service department.
Venting (without function)
Check fluff filter
The fluff filter is clogged.
Action: Clean the fluff filter at the end of the
programme.
Note:
The "Drying", "Cool air" and "Anti-crease" indi-
cator lights flash if there is a power cut or if a
programme has been interrupted (e.g. when a
door has been opened and shut). They are
not indicative of a fault. The lights will stop
flashing when the "Start" button is pressed.
This only applies to gas heated machines
Gas heating
The "Gas heating" indicator light goes out and
the dryer switches itself off after approx. 7
minutes, when
The site gas supply to the machine is inter-
rupted (e.g. gas stop valve has not been
opened).
Action: Open the gas stop valve.
an ignition fault occurs after the start of a
programme.
Action: To restore operation switch the ma-
chine off and then on again, and press the
"Start" button.
The venting duct is blocked or badly re-
stricted.
Action: Check the venting duct and clean if
necessary.
The gas connection pressure is too low
(there may be a drop in pressure in the gas
supply network).
Action: Inform your gas supplier.
If the fault is still present after these measures
have been taken, it is essential to call a Miele
authorised service technician to deal with the
fault.
Heating Gas heating
(flashes) (goes out)
Safety period
(flashes)
Venting
Check fluff filter
(lights up)
On
Drying
Cool air
Anti-crease
Check venting
Check fluff filter