EasyManua.ls Logo

MILL GL400WIFI3 - Page 8

MILL GL400WIFI3
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
EN
Resetting the heater
Memory function
"Open window" function
The heater remembers all the temperature settings and will automatically return to the
desired temperature after a power failure. If your heater is connected to WiFi it will
automatically reconnect with WiFi (where all temperatures are saved) after a power cut.
The heater has an “open window” function that is activated instantly when it registers a
sudden drop in temperature with more than 5 degrees Celsius in 15 minutes. The heater will
automatically stop heating and FO will be visible in the display of the heater.
While in open window mode, it will maintain 5°C (to avoid frost damage).
The heater will automatically start heating again if temperature increase by at least
3 degrees within 15 minutes.
You can switch the heater back to normal mode by pressing the settings button 1 time.
Open window function can be disabled/enabled by pressing and holding the settings
button for 3 seconds. You can also disable/enable open windows function from the app
if configured to WiFi.
Turn off the heater’s main switch. Turn the heater back on, within 5 seconds press and
hold .After 20 seconds the display will show "Fr", once you see "Fr" release
and the heater will reset to factory settings.
actual temperature in the room. This can be caused by several reasons, however, the
most common is that the heater is placed in a fair distance from where you usually
reside. When you set the temperature to for example 22 degrees, it is only natural that
you expect the same temperature where your sofa is placed for instance. However,
the temperature sensor is placed on the product itself, and therefore a deviation in
temperature may occur. To adjust this, all Mill heaters are equipped with a calibration
function, which enables you to adjust the temperature registered by the heater. N.B!
The room must have achieved a stable temperature before any calibration
(Can be done even if you are connected to WiFi)
Press 2 times and use + or - to set the actual temperature observed in the room.
Confirm with or wait 5 seconds for automatic confirmation.
For models PA500LWIFI3M, GL500LWIFI3M, PA900WIFI3MP, GL900WIFI3MP,
PA1000WIFI3MP and GL1000WIFI3MP please follow the steps below to activate
temperature calibration:
Press to enter menu and use + and - button to navigate the menu until you
see "CAL" in the display. Press to enter calibration mode. The registered room
temperature will blink on the display. Use + or - button to set the actual temperature
observed in the room. Confirm with or wait 10 seconds for automatic confirmation.
For models PA500LWIFI3M, GL500LWIFI3M, PA900WIFI3MP, GL900WIFI3MP,
PA1000WIFI3MP and GL1000WIFI3MP please follow the steps below to reset
the heater:
Press to enter menu. Use + and - button to navigate the menu until you see "Hr"
in the display. Press to enter reset mode. Press + or - button to choose between
"YES" or "NO". Select option by pressing . After selecting "YES", the "YES" label
blinks twice and heater restarts. For a few seconds the whole display is off, before
the heater starts normal operation.