EasyManuals Logo

Miller ICE-12C User Manual

Miller ICE-12C
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
OM-1593 Page 13
14. Routine Maintenance
! Turn Off power source
and disconnect
input power plug
before maintaining.
. 25 ampere torch is shown.
Maintenance schedule for
50 and 80 ampere torches is the same.
n = Check Z = Change ~ = Clean l = Replace
* To be done by Factory Authorized Service Agent
Reference
Each
Use
Use
n Check Gas/Air Pressure n Torch Tip, Electrode,
And Shield Cup
Every
Week
Week
n Shield Cup Shutdown
System
Every
Every
3
l Cracked Parts n Gas/Air Hose n Torch Body, Cable
3
Months
n Tape Torn Outer
Covering
1 Torch Shield Cup
Turn Power On and loosen shield
cup. If shutdown system works
properly, Ready light on power
source goes off and Cup light com-
es on. If not, turn power Off and
check for proper gas/air pressure,
blocked or leaking hose, or loose
shield cup.
If system works properly, retighten
cup and reset power.
15. Shield Cup Shutdown System
Ref. 801 300-A / Ref. 801 300-A
1
. Power source Power switch must be reset whenever cup shutdown
system is activated. Always turn Off power source when changing or
checking consumables.
. Procedure applies to all torch models.
1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Miller ICE-12C and is the answer not in the manual?

Miller ICE-12C Specifications

General IconGeneral
BrandMiller
ModelICE-12C
CategoryFlashlight
LanguageEnglish

Related product manuals