9. Installing 50 Ampere, 55 Ampere or 80 Ampere Torch And Using Trigger Safety Lock
801 395-A / 801 545-A
! Turn Off power source, and
disconnect input power plug
from receptacle before
installing torch.
1 Power Source
2 Torch Connection Receptacle
3 Plug
4 Threaded Collar
5 Keyway
To connect to receptacle, align
keyway, insert plug, and tighten
threaded collar.
6 Trigger
3
4
5
1
2
NOTICE ā Be sure plug is correctly
aligned before tightening collar to
avoid cross-threading.
6
Trigger Locked Trigger Unlocked
. The 50 ampere torch is shown in the illustrations below.
The procedure for the 55 ampere and 80 ampere
torches is identical.
. The 55 ampere torch can be used on a 50 ampere model
power source. The 50 ampere torch cannot be used on
a 55 ampere model power source. The 55 ampere pow-
er source has a special torch connection receptacle that
prevents the 50 ampere torch from being connected.