10. Installing Either 80 Ampere Or 100 Ampere T/TM Torch
! Turn off power source and
disconnect input power.
1 Torch Connector
2 Quick Connect Collar
3 Nipple
4 Receptacle
5 Securing Pin
To connect torch:
Push torch connector onto
receptacle and quick connect until
collar secures nipple.
Rotate securing pin to lock
connector to unit.
To disconnect torch:
Rotate securing pin to unlock
connector from unit.
Push quick connect collar back
towards unit to release nipple, and
pull torch connector away from unit.
804 055-A
2
1
3
4
5