Explains risks associated with operating the instrument and provides supplemental safety information.
Defines signal words used to identify safety and property damage messages.
Lists symbols used to highlight conditions that could cause injury to personnel.
Advises to keep safety labels clean, legible, and to replace them if necessary.
Instructs to switch off and unplug the instrument if it's not working properly.
Details risks from electrical devices like shock, short circuits, and overheating.
Discusses laser and LED radiation risks and safety measures.
Outlines risks from biohazardous material and necessary safety precautions.
Covers risks of improper servicing and guidelines for safe transportation.
Provides information on proper disposal of electrical and electronic equipment (WEEE).
Explains the patented microchip technology for fluorescence-based cell sorting.
Describes the instrument as a research-use only benchtop device for microchip-based cell sorting.
Lists components provided with the MACSQuant Tyto Sorter.
Lists required consumables for the MACSQuant Tyto Sorter, including order numbers.
Provides step-by-step instructions for safely unpacking the instrument.
Details how to connect the monitor, HDMI, and keyboard to the instrument.
Step-by-step guide to power on the MACSQuant Tyto Sorter and its touchscreen.
Instructions for safely shutting down the software and powering off the instrument.
Explains how to scan the 2D code on the cartridge before use.
Guides on how to orient and place the cartridge into the instrument.
Describes how to stop the sorting process and remove the cartridge.
Recommends disinfectants and procedures for decontaminating the instrument.
Provides instructions on how to safely replace fuses in the instrument.
Lists potential causes and solutions for cartridge alignment errors.
Describes issues with continuous alignment and troubleshooting steps.
Explains why the system might eject a cartridge failing to pressurize.
Discusses issues where the valve does not move and potential causes.
Addresses issues with clogged sort channels due to air bubbles or debris.
Explains causes for input filter clogging leading to reduced sort rates.
Describes how to identify and resolve false negative populations in dot plots.
Lists common reasons for low yield after sorting and their solutions.
Identifies causes for low purity of sorted target cells and suggests corrective actions.
Provides detailed specifications of the MACSQuant Tyto Sorter, including model, dimensions, power, and ports.
Details optical parameters such as laser excitation, emission detectors, and fluorescence performance.
Lists fluidic parameters like sample volume, cell flow rate, sorting rate, and pressure.
Outlines measurement parameters and signal processing capabilities.
States the instrument's compliance with EU directives and harmonized standards.
Describes the real-time diagnostic service for remote assistance.
Provides contact details for Miltenyi Biotec Technical Support and headquarters.