Accuracy | ±0.01 pH |
---|---|
Dimensions | 145 x 80 x 36 mm |
Weight | 230 g |
Temperature Compensation | Automatic from 32°F to 122°F (0°C to 50°C) |
Environment | 0°C to 50°C (32°F to 122°F), 0 to 85% RH (non-condensing) |
Battery Type | 9V battery |
Display | LCD |
Battery | 1 x 9V (included) |
Details specifications for the pH electrode (MA917B/1) and temperature probe (MA831R).
Explains buttons and display elements on the MW150 front panel.
Explains buttons and display elements on the MW151 front panel.
Details connection ports on the MW150 rear panel.
Details connection ports on the MW151 rear panel.
Explains indicators and data displayed on the MW150 LCD screen.
Explains indicators and data displayed on the MW151 LCD screen.
Describes features and design of the MA917B/1 pH electrode.
Details construction and function of the MA831R temperature probe.
Covers powering the meter and battery conservation.
Instructions for mounting the electrode holder and connecting the pH and temperature probes.
Guidance on electrode conditioning, handling, storage, and regular maintenance.
Configures basic meter settings: pH info, calibration warnings, date, time, auto-off, sound, units.
Configures MW151 features: export, logging type, custom buffers, resolution, separator.
Guides on preparing buffers and performing pH calibration using standard or custom buffers.
Details 5-point calibration, custom buffer usage, and calibration notes.
Explains how to clear calibration data and what 'CAL EXPIRED' warning means.
Details how to take pH measurements and explains MTC mode operation.
Explains warnings for electrode condition, buffer checks, and buffer contamination.
Details warnings for standard temperature, buffer contamination, and measurement limits.
Explains warnings for out-of-calibration range and out-of-specification measurements.
Covers preparing the electrode and taking ORP readings in mV mode.
Explains how to store, recall, and clear measured values on the MW150.
Describes manual, stability, and interval logging methods supported by the MW151.
Details the steps for performing manual log on demand and log on stability.
Guides on accessing and viewing stored log records and lot information.
Explains how to delete entire lots or individual logs from manual and stability logs.
Details how to connect to a PC and export logged data in CSV format.
Explains exporting data to a USB flash drive, including overwriting existing files.
Lists and explains warnings related to data management and logged data.
Explains how to store and recall calibration data, including pH, buffer, time, and electrode status.
Explains GLP status indicators like 'EXP WARN DIS' and 'NO CAL'.
Outlines the warranty terms for the instruments and probes, including exclusions.