EasyManua.ls Logo

Milwaukee MW804 User Manual

Milwaukee MW804
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
ACCESSORIES
MI60P Replaceable probe for MW803 & MW804
M10030B
12.88 mS/cm calibration solution, 20ml
sachet, 25 pcs
M10031B
1413 µS/cm calibration solution, 20ml
sachet, 25 pcs
M10032B
1382 ppm TDS Calibration Solution, 20 ml
sachet, 25 pcs.
M10038B
6.44 ppt TDS Calibration, 20 ml sachet,
25 pcs.
MA9060
12.88 mS/cm calibration solution, 230ml
bottle
MA9061
1413 µS/cm calibration solution, 230ml
bottle
MA9062
1382 ppm TDS Calibration Solution,
230mL bottle
M10016B Cleaning solution, 20 ml sachet, 25 pcs
M10000B Rinse solution, 20 ml sachet, 25 pcs
M10004B pH 4.01 buer, 20 ml sachet, 25 pcs.
M10007B pH 7.01 buer, 20 ml sachet, 25 pcs.
M10010B pH 10.01 buer, 20 ml sachet, 25 pcs.
MA9004 pH 4.01 buer, 230 ml bottle
MA9007 pH 7.01 buer, 230 ml bottle
MA9010 pH 10.01 buer, 230 ml bottle
MA9006 pH 6.86 buer, 230 ml bottle
MA9009 pH 9.18 buer, 230 ml bottle
MA9015 Electrode storage solution, 230 ml
CERTIFICATION
Milwaukee Instruments conform to the CE European
Directives.
Disposal of Electrical & Electronic Equipment. Do not
treat this product as household waste. Hand it over to the
appropriate collection point for the recycling of electrical
and electronic equipment.
Disposal of waste batteries. This product contains
batteries. Do not dispose of them with other household
waste. Hand them over to the appropriate collection
point for recycling.
Please note: proper product and battery disposal
prevents potential negative consequences for human
health and the environment. For detailed information,
contact your local household waste disposal service or
go to www.milwaukeeinstruments.com (USA & CAN)
or www.milwaukeeinst.com.
SPECIFICATIONS
Range
0.00 to 14.00 pH
0 to 3999 µS/cm (MW803)
0 to 2000 ppm (MW803)
0.00 to 20.00 mS/cm (MW804)
0.00 to 10.00 ppt (MW804)
0.0 to 50.0 °C / 32.0 to 122.0 °F
Resolution
0.01 pH
1 µS/cm / 1 ppm (MW803)
0.01 mS/cm / 0.01 ppt (MW804)
0.1 °C / 0.1 °F
Accuracy (@25°C)
0.05 pH
2% FS (EC/TDS)
0.5 °C / ±1 °F
TDS Factor 0.45 to 1.00 (CONV)
Temperature
Compensation
Automatic, with ß=0.0 to 2.4%/°C
Calibration
Automatic, 1 point for EC and 1 or
2points for pH
Probe
Replaceable
MI60P
Environment 0 to 50 °C; 100% RH max.
Battery Type 4 x 1.5V; IEC LR44, A76
Battery Life Approx. 100 hours of use
Auto-o After 8 min. of non-use
Dimensions /
Weight
200 x dia 38 mm / 100 g
RECOMMENDATION
Before using this product, make sure it is entirely suitable
for your specific application and for the environment in
which it is used. Any modification introduced by the user
to the supplied equipment may compromise the tester’s
performance. For your and the tester’s safety do not use
or store the tester in hazardous environment. To avoid
damage or burn, do not perform any measurement in
microwave ovens.
WARRANTY
These instruments are warranted against defects in
materials and manufacturing for a period of 2years from
the date of purchase. Probe is warranted for 6 months.
This warranty is limited to repair or free of charge
replacement if the instrument cannot be repaired.
Damage due to accidents, misuse, tampering or lack
of prescribed maintenance is not covered by warranty.
If service is required, contact your local Milwaukee
Instruments Technical Service. If the repair is not covered
by the warranty, you will be notified of the charges
incurred. When shipping any instrument, make sure it is
properly packaged for complete protection.
Milwaukee Instruments reserves the right to make
improvements in design, construction and appearance of its
products without advance notice.
ISTMW803 11/20
USER MANUAL
SATISFACTION
GUARANTEED
MW803, MW804
MAX Waterproof 4-in-1
pH/EC/TDS/Temperature
Testers
Distributor in Australia
Pacific Sensor Technologies Pty Ltd
Unit 4, 3 Neutron Place Rowville, VIC 3178 Australia
1300 662 720 | sales@pacificsensortech.com.au
www.pacificsensortech.com.au
Question and Answer IconNeed help?

Do you have a question about the Milwaukee MW804 and is the answer not in the manual?

Milwaukee MW804 Specifications

General IconGeneral
ModelMW804
CategoryTest Equipment
DisplayLCD
Dimensions145 x 80 x 36 mm
Weight230 g
Measurement FunctionsTemperature
Auto Power OffYes

Summary

Specifications

Range

Defines the measurement limits for pH, EC, and TDS.

Resolution

Specifies the smallest increment the tester can display for measurements.

Accuracy

Indicates the precision of the tester's readings at 25°C.

TDS Factor

Allows adjustment of the TDS conversion factor for measurements.

Temperature Compensation

Details the automatic temperature compensation method.

Calibration

Describes the automatic calibration process for the tester.

Probe Replaceable

Identifies the compatible replaceable probe model.

Environment

Specifies operating conditions for temperature and humidity.

Battery Type

Lists the required battery type for the tester.

Battery Life

Estimates the duration of battery operation.

Auto-off

States the time after which the tester automatically shuts down.

Dimensions / Weight

Provides physical size and weight of the tester.

Certification and Disposal

CE and RoHS Compliance

Confirms adherence to European Directives for safety and materials.

Equipment Disposal

Guidance on proper recycling of electrical and electronic equipment.

Battery Disposal

Instructions for safe and responsible disposal of batteries.

Usage Recommendations and Warranty

Product Usage Recommendations

Advises on suitability and safe usage environments for the tester.

Warranty Terms

Details the warranty period and conditions for the instrument and probe.

Operational Guide

Tester Operation Steps

Covers turning the tester on/off, immersing the probe, and freezing readings.

Setup

Temperature Unit Selection

Allows selection between Celsius (°C) and Fahrenheit (°F).

EC Mode Settings

Configuration options for TDS factor and temperature coefficient (BETA).

pH Mode Settings

Selection of calibration buffer sets for pH measurements.

Measurement and Calibration Procedures

EC Measurement and Calibration

Step-by-step guide for measuring EC and performing calibration.

pH Measurement and Calibration

Step-by-step guide for measuring pH and performing calibration.

Maintenance and Replacement

Probe Replacement

Instructions on how to safely remove and replace the tester probe.

Battery Replacement

Guidance on how to replace the tester's batteries.

Related product manuals