Minarik DLC600 Specifications

General IconGeneral
Display TypeLCD
Input Voltage24 VDC
Communication InterfaceRS-232, RS-485
Operating Temperature0°C to 50°C
Storage Temperature-20°C to 70°C
Enclosure RatingNEMA 4X

Summary

Safety First!

Safety Warnings

Important safety tips and warnings to be read before performing procedures.

Section 1. Introduction

Basic Operation Principles

Explains how the DLC600 regulates motor speed via frequency comparison and feedback.

Section 2. Specifications

Technical Specifications

Lists electrical, environmental, and performance specifications for the DLC600.

Section 3. Dimensions

Physical Dimensions

Provides detailed measurements and diagrams of the DLC600 unit.

Section 4. Installation

Mounting Instructions

Guidelines for securely mounting the DLC600 unit, avoiding hazards.

Panel Mounting

Steps for cutting a panel opening and installing the DLC600 unit.

Wiring Connections

Details on connecting line voltage, output, feedback, inhibit, and frequency terminals.

Shielding Guidelines

Recommendations for using shielded cables to prevent electrical noise interference.

Terminal Connections Overview

Summarizes connections for Line Voltage, Output, Feedback, Inhibit, and Frequency terminals.

Section 5. Operation

Feedback Device Selection

Criteria and calculations for selecting appropriate feedback devices based on RPM and PPR.

Line Voltage Switch (SW501)

How to set the voltage input using SW501.

Encoder Power Supply Voltage (SW502)

Setting the voltage for external encoders using SW502 DIP switch 1.

Feedback Device Selection (SW502)

Configuring feedback device type via SW502 DIP switches 2 & 3.

Reference Signal Selection (SW502)

Selecting internal or external reference signals using SW502 DIP switches 4 & 5.

Section 6. Calibration

Calibration Procedure

Explains how to adjust trim pots for optimal drive response and speed regulation.

MIN and MAX Settings

Steps to set the MIN and MAX trim pots for motor speed control.

Section 7. Programming

Parameter Calculation

Calculate parameters like SSF, Load Response, Gate Time, and Decimal Point.

Programming Mode and Input

Access programming mode and input calculated parameters and speed settings.

Programming Examples

Practical examples of calculating and programming parameters.

Section 8. Leader-Follower Applications

Leader-Follower Overview

Explains using the DLC600 to follow an external frequency for synchronized operation.

Leader-Follower Example with Encoder

Step-by-step guide for setting up a leader-follower system with a leader encoder.

Leader-Follower Example with Two DLC600s

Instructions for configuring two DLC600 units for leader-follower operation.

Section 9. Troubleshooting

Motor Not Running Issues

Common causes and solutions when the motor fails to start.

Motor Speed Lock Issues

Diagnosing and resolving problems with the motor not achieving or maintaining set speed.

Motor Speed Difference Issues

Troubleshooting fixed speed differences between set and actual motor speeds.

Unconditional Warranty

Warranty Terms and Disclaimer

Details on Minarik Drives's product warranty, disclaimer, and limitations of liability.