101
7−6−2. Setting related with the Stabilized filter.
D Set the data to apply the Stabilized filter with the function F−17. The stabilized filter
width per set value “n” can be obtained through the display conversion by using the
following formula.
[Stabilized filter data width]=[Set value of F−17]×[Display increment value]
For example, when the setting of function F−17 is “00010” and the display increment is
“D=5”, then
[Stabilized filter data width]=10×5
=50
D Data width supervisory time for the Stabilized filter can be set with the function F−16.
D The digital filter for Stabilized filter can be set with the function F−15.
Setting from “00000” to “00006” is possible, and strength of the stabilization filter is
decided depending on the set value. The filter works strongly depends on growing of the set
value.
D Moreover, when the digital filter has set with the function F−04, the calculation
processing of the stabilization filter is executed as a result of the calculation process being
done with the digital filter.
● When the stabilization filter is effective, the filter might strengthen
more than cut−off frequency in the paragraph 7−3−1.
Effective
Ineffective
Digital filter for
stabilized filter
Time
Stabilized filter
time width
Load
variation
width
Load
Stabilized filter
time width
Load variation
width
Stabilized filter
data width
Stabilized filter
data width
Stabilized filter
time width
Load variation
width
Stabilized filter
data width