121
D F−06 Setting the function key lock
Initial value=00000 10
0
digit:ON/OFF of CHECK value
(Press the
key together with the key)
10
1
digit:ON/OFF of the A/Z function
A/Z ON(
)、A/Z OFF()
10
2
digit:Call the change mode of S※ setting (),
10
3
digit:Execution of zero set()
10
4
digit:Call the function mode()
※Key lock cancellation is made by setting “0”, and key lock is made by setting “1”.
Moreover, when the “Call the function mode” is locked, the function mode can be
entered after pressing the the
key for more than 2 seconds together with the
key for more than 1 second.
D F−08 Setting zero tracking data width
Initial value=00000 00000=Zero tracking OFF
Setting range:00000〜00099
Unit:0.5D
Data width of 49.5D with the setting “00099”.
※Effective only when the value of 00001〜00099 is set with the F−09.
D F−09 Setting zero tracking time width
Initial value=00020 00000=Zero tracking OFF
Setting range:00000〜00099
Unit:0.1 s
Time width of 9.9 s with the setting “00099”.
※Effective only when the value of 00001〜00099 is set with the F−08.
D F−10 Setting of the target of HOLD
Initial value=11111 10
0
digit:Load display
10
1
digit:Comparator S0 open collector output, LED display
10
2
digit:Comparator S1, S2, S3 and S4 open collector output,
LED display
10
3
digit:Analog output
10
4
digit:Optional BCD output
※Out of the HOLD target at the setting “0”, and the HOLD target is available at the
setting “1”.
D F−11 Setting the CHECK value
Initial value=00003 Setting range:00000〜00024
Unit:0.1 mV/V
Approx. 2.4 mV/V CHECK value at the setting “00024”.