122
D F−12 Setting bridge power supply voltage
Initial value=00000 00000:10 V
00001:5V
00002:2.5 V
D F−15 Setting digital filter for stabilized filter
Initial value=00002 00000=Stabilized filter OFF
Setting range:00000〜00006
※Strength of the digital filter for the stabilization filter is selected.
The influence on the display such as the vibrations decreases so that the filter may
strengthen when the figure grows.
※Effective only when setting is made with the value from 00001 to 00099 with the
F−16, and the value from 00001 to 00999 is set with the F−17.
D F−16 Setting time width for stabilized filter
Initial value=00020 00000=Stabilized filter OFF
Setting rage:00000〜00999
Unit:0.01 s
Time width of 9.99 s at the setting of “00999”.
※Effective only when the value from 00001 to 00006 with the F−15 and the value from
00001 to 00999 with the F−17 are set.
D F−17 Setting data width for stabilized filter
Initial value=00020 00000=Stabilized filter OFF
Setting rage:00000〜00999
Unit:1D
Data width of 999D at the setting of “00999”.
※Effective only when the value from 00001 to 00006 with the F−15 and the value from
00001 to 00999 with the F−16 are set.
D F−20 Setting the target of analog output
Initial value=00000 00000:Gross weight
00001:
Net weight
D F−21 Display value at the time of the minimum analog output
Initial value=00000 Setting rage −99999〜99999
D F−22 Display value at the time of the maximum analog output
Initial value=02000 Setting rage −99999〜99999
D F−30 Setting comparator operation
Initial value=11111 0=OFF
1=ON
10
0
digit:Comparator S0
10
1
digit:Comparator S1
10
2
digit:Comparator S2
10
3
digit:Comparator S3
10
4
digit:Comparator S4