EasyManua.ls Logo

Minebea CSD-891B - Page 137

Default Icon
230 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
123
D F−31 Setting the target of comparator
Initial value=00000 0=Gross weight
1=Net weight
10
0
digit:Comparator S0
10
1
digit:Comparator S1
10
2
digit:Comparator S2
10
3
digit:Comparator S3
10
4
digit:Comparator S4
※The comparator S0 is effective in the setting 00007 by F−33.
D F−32 Setting the direction of comparator
Initial value=00000 0=or more
1=or less
10
0
digit:Comparator S0
10
1
digit:Comparator S1
10
2
digit:Comparator S2
10
3
digit:Comparator S3
10
4
digit:Comparator S4
※The comparator S0 is effective in the setting 00007 by F−33.
D F−33 Setting applicable condition for the comparator S0
Initial value=00000 00000=ON when load display value≧the maximum display value
00001=ON when both S1 and S2 open collector output are OFF.
00002=ON when both S1 and S3 open collector output are OFF.
00003=ON when both S1 and S4 open collector output are OFF.
00004=ON when both S2 and S3 open collector output are OFF.
00005=ON when both S2 and S4 open collector output are OFF.
00006=ON when both S3 and S4 open collector output are OFF.
00007=Operation whichever “open collector ON over the set
value” or “open collector ON less than the set value”
00008=Interlocked with HOLD LED
00009=Interlocked with A/Z LED
00010=Interlocked with LOCK LED
00011=ON when the detection of stability
D F−34 Setting the condition of Hysteresis operation for comparator
Initial value=00000 00000=ON delay
00001=OFF delay
D F−35 Hysteresis data width OFF
Initial value=00000 00000=Hysteresis data width OFF
Setting rage:00000〜00099
Unit:1D
Data width of 99D at the setting of “00099”.