S-45
Touch Panel
Display
Setting (The default is ).
Feed (FD) Set the correction value for the original scanning position in the FD
direction when the EDH is used.
Feed (CD) Set the correction value for the original scanning position in the CD
direction when the EDH is used.
S-ADF Feed (FD) Set the correction value for the original scanning position in the FD
direction in the single feed mode.
S-ADF Feed (CD) Set the correction value for the original scanning position in the CD
direction in the single feed mode.
Regist Loop (1) Set the length of the loop formed in the 1-sided original before the
Registration Roller of the EDH.
Regist Loop (2) Set the length of the loop formed in the 2-sided original before the
Registration Roller of the EDH.
Feed Position Set the target stop position of the Scanner during scanning by the
EDH.
Highlighted
-4.0 to +4.0 ( )
0.0 mm
-3.0 to +3.0 ( )
0.0 mm
-4.0 to +4.0 ( )
0.0 mm
-3.0 to +3.0 ( )
0.0 mm
-5.0 to +5.0 ( )
0.0 mm
-5.0 to +5.0 ( )
0.0 mm
Setting