EasyManua.ls Logo

Minolta DI450 - C004 E: Power Supply Unit Cooling Fan Motor 1 S Failure to Turn C004 F: Power Supply Unit Cooling Fan Motor 2 S Failure to Turn

Minolta DI450
271 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
T-42
(6) C004E: Power Supply Unit Cooling Fan Motor 1’s failure to turn
C004F: Power Supply Unit Cooling Fan Motor 2’s failure to turn
C004E
Relevant Electrical Parts
Power Supply Unit Cooling Fan Motor 1
(M16)
Power Supply Unit Cooling Fan Motor 2
(M15)
Master Board (PWB-A)
Power Supply Board (PWB-C)
Step Check Result Action
1 Power Supply Unit Cooling Fan Motor 1 rota-
tion: the voltage across PJ3C-1 on Power Sup-
ply Board and GND is DC24V after the
malfunction has been reset.
NO Change Power Supply
Board.
2 Power Supply Unit Cooling Fan Motor 1 rota-
tion: the voltage across PJ3C-3 on Power Sup-
ply Board and GND is DC5V after the
malfunction has been reset.
YES Check motor for installa-
tion.
Change motor.
NO Change Power Supply
Board.
PWB-C
PJ3C-1 (DC24V)
PJ3C-2 (GND)
PJ3C-3 (M16 LD)
PJ6A-13(M15 LD)
PJ6A-12(GND)
PJ6A-11(DC24V)
PWB-A
M16
M15
CN115
1
2
3
3
2
1
4002C23TAA