EasyManua.ls Logo

Minolta DI450 - Page 245

Minolta DI450
271 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
T-54
C0910, C0914
C0920, C0924
Step Check Result Action
1
Lift-Up Motor turns when the 2
nd
Drawer is slid
out and then back in.
NO Correct drive coupling.
2
2
nd
Drawer Lift-Up Motor rotation: the voltage
across PJ3A-13B on Master Board and GND is
DC0V (motor deenergized) and DC24V (motor
energized) after the 2
nd
Drawer has been slid
back in.
YES Change motor.
NO Change Master Board.
3
I/O check for 2
nd
Drawer Lift-Up Motor Pulse
Sensor operation: the voltage across PJ3A-
11B on Master Board and GND changes in the
range between DC0V and DC5V while 2
nd
Drawer Lift-Up Motor is turning.
YES Change Master Board.
NO Correct drive coupling.
Change sensor.
4
I/O check for 2
nd
Drawer Paper Lift-Up Sensor:
the voltage across PJ4A-12B on Master Board
and GND is DC0V (sensor unblocked) and
DC5V (sensor blocked).
YES Change Master Board.
NO Change sensor.
Step Check Result Action
1
Lift-Up Motor turns when the 1
st
Drawer is slid
out and then back in.
NO Correct drive coupling.
2
1
st
Drawer Lift-Up Motor rotation: the voltage
across PJ3A-13A on Master Board and GND is
DC0V (motor deenergized) and DC24V (motor
energized) after the 1
st
Drawer has been slid
back in.
YES Change motor.
NO Change Master Board.
3
I/O check for 1
st
Drawer Lift-Up Motor Pulse
Sensor operation: the voltage across PJ3A-
11A on Master Board and GND changes in the
range between DC0V and DC5V while 1
st
Drawer Lift-Up Motor is turning.
YES Change Master Board.
NO Correct drive coupling.
Change sensor.
4
I/O check for 1
st
Drawer Paper Lift-Up Sensor:
the voltage across PJ4A-6B on Master Board
and GND is DC0V (sensor unblocked) and
DC5V (sensor blocked).
YES Change Master Board.
NO Change sensor.

Table of Contents