D-61
(2) Removal of the Upper Fusing Paper Separator Fingers
(3) Cleaning of the Upper Fusing Paper Separator Fingers
(4) Cleaning of the Lower Fusing Paper Separator Fingers
(5) Cleaning of the Entrance Guide Plate
1. Remove the Upper Fusing Guide Plate Assy.
2. Remove five springs.
3. Slide out the shaft to remove five Upper Fusing
Paper Separator Fingers.
4002D177AA
1. Remove the Upper Fusing Guide Plate Assy.
2. Using a soft cloth dampened with oil, wipe the five
Upper Fusing Paper Separator Fingers clean of
dirt.
4002D178AA
1. Remove the Fusing Unit Front Cover.
2. Swing open the Lower Fusing Guide Plate Assy.
Using a soft cloth dampened with oil, wipe the five
Lower Fusing Paper Separator Fingers clean of
dirt.
4002D179AA
1. Using a soft cloth dampened with alcohol, wipe
clean the Entrance Guide Plate.
4002D180AA