EasyManua.ls Logo

Minolta SRT 101 - C. Assembly and mounting of View-finder and Exposure meter block

Minolta SRT 101
43 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cc.
Assembly
and
mounting
of
View-finder
and
Exposure
meter
block
Check
point
before
assembly
;
Fig.
23
2.
*
Check
if
the
pentagon
prism(5803),
the
condenser
lens
(5804)and
the
fresnel
lens(5805)
are
free
from
scratch
and
stain
or
dust.
Fit
the
fresnel
lens(5805)
into
the
condenser
holder
(5064)
with
the
portion
having
on
groove
of
the
fresnel
being
located
downwardly
and
then
overlay
thereon
the
interval
seat
(5066).
Clean
the
surface
of
the
fresnel
lens(5805)
on
which
is
placed
the
condenser
lens
(5804).
Insert
the
condenser
pressure-B(5065)and
the
condenser
pressure-F
(5067)
in
the
direction
shown
in
the
Figure,
and
then
overlay
the
prism
holder(so25
set)on
the
condenser
holder
(5064),
which
is
held
in
position
from
the
beneath
thereof
by
means
of
four
setscrews
(B31-1.7
2).
Mount
by
means
of
one
middle
pulley-B
axis(9154)
and
one
setecrew(Bl1-1.7X2.5)
with
care
for
the
meter
needle
of
the
meter
moving
coil(4391).
Insert
the
AY
middle
pulley-B
(4073)into
the
pulley-B
axis(9154)
and
also
embed
the
coupling
washer(E-0.8)
into
the
pulley-B
axis,
Clean
the
surface
of
the
condenser
lens(5804)
and
insert
the
pentagon
prism(5903
set)
into
the
prism
holder
(so25
set),
Hold
the
prism
pressure
spring(5069)
in
position
by
means
of
one
setscrew
(B11-1.73)
and
engage
the
bended
portion
of
the
pressure
spring
(5069)
with
the
pressure
support
spring
(S072).
Withdraw
the
AV
coupling
string(4080)
of
the
camera
body
to
the
front
side
of
the
camera
body.
Then
mount
the
viewfinder
and
the
meter
block
on
the
camera
body,
in
such
a
manner
that
they
may
not
clamp
the
lead
wires,
by
means
of
threeprism
holder
setscrews
(9132)
temporarily.
Adjustment
of
parallax;
Fig.
24
Hold
the
eye-piece
frame(S061
set)
in
position
by
means
of
two
setscrews(9158).
Mount
the
standard
lens
to
the
camera
body
and
set
it
to
the
infinity
position.
Then
look
the
image
of
the
collimator
and:
*
When
the
image
is
lowered
as
illustrated
in
the
Figure
right,
lower
the
viewfinder
frame
and;
*
When
the
image
is
raised
as
illustrated
in
the
view-
finder
frame.
Adjustment
of
finder
back:
Loosen
three
setscrews(9132)
for
the
prism
holder
and
raise
or
lower
three
adjustment
screws
(9101)
for
adjusting
focus.
(See
Fig.
25).

Related product manuals