SERVICE MANUAL
CONTENTS
1. REFERENCE MANUAL
...................................
3
2. SAFETY PRECAUTION
...................................
4
3. SPECIFICATIONS
............................................
6
4. PART NAMES AND FUNCTIONS
..................
8
5. OUTLINES AND DIMENSIONS
.......................
9
6. WIRING DIAGRAM
.........................................
11
7. FIELD WIRING
...............................................
17
8. WATER SYSTEM DIAGRAM
.........................
19
9. CONTROLS
...................................................
22
10. TROUBLESHOOTING
...................................
43
11. DISASSEMBLY PROCEDURE
......................
60
12. SUPPLEMENTARY INFORMATION
.............
80
13. SERVICE AND MAINTENANCE
...................
81
Note:
• This manual describes
service data of
Hydrobox only.
MAIN REMOTE
CONTROLLER
PARTS CATALOG (OCB712)
HYDROBOX
October 2020
HYDROBOX
No. OCH712
REVISED EDITION-C
[Model Name]
EHSD-MED
EHSD-VM2D
EHSD-VM6D
EHSD-YM9D
EHSD-YM9ED
EHSD-TM9D
ERSD-MED
ERSD-VM2D
ERSD-VM6D
ERSD-YM9D
[Service Ref.]
Refer to page 2.
EHSC-MED
EHSC-VM2D
EHSC-VM6D
EHSC-YM9D
EHSC-YM9ED
EHSC-TM9D
ERSC-MED
ERSC-VM2D
ERSC-VM6D
ERSC-YM9D
Revision:
•
ERSD-VM6D, ERSD-
YM9D, ERSC-VM6D,
ERSC-YM9D and
ERPX series have been
added.
•
Some descriptions
have been modified
in
REVISED EDITION-C
.
OCH712B is void.
EHSE-MED
EHSE-YM9ED
ERSE-MED
ERSE-YM9ED
EHPX-VM2D
EHPX-VM6D
EHPX-YM9D
EHPX-MED
EHPX-YM9ED
ERPX-MD
ERPX-VM2D
ERPX-VM6D
ERPX-YM9D

Questions and Answers

  • C
    Connie MathisAug 3, 2025
    What to do if my Mitsubishi Electric Water System has a non-recurring logged problem?
    • J
      Jonathon NewmanAug 3, 2025
      If your Mitsubishi Electric Water System experiences a non-recurring problem that is logged, begin by checking for temporary causes such as the operation of safety devices on the refrigerant/water circuit including compressor, poor wiring, electrical noise. Also, re-check the symptom and the installation environment, refrigerant amount (Split systems only), weather conditions at the time of the fault, etc. After checking these potential causes, reset the check code logs, service the unit, and restart the system.
  • D
    David FuentesAug 18, 2025
    What to do if a Mitsubishi Electric EHSD-MED has a non-recurring problem and it is not logged?
    • S
      Sarah McdowellAug 18, 2025
      If your Mitsubishi Electric Water System has a non-recurring problem that is not logged, start by rechecking the abnormal symptom. Then, identify the cause of the problem and take corrective action according to Table "10-5. Troubleshooting by inferior phenomena". If no obvious problem can be found, continue to operate the unit.

Summary

Reference Manual Overview

Safety Precautions

General Safety Precautions

Important warnings and cautions for safe operation and installation.

Specifications

Part Names and Functions

Outlines and Dimensions

Technical Drawings

Detailed diagrams showing unit dimensions and connection points.

Wiring Diagrams

Electrical Wiring Schematics

Diagrams illustrating electrical connections for various model configurations.

Field Wiring

Wiring Options for Hydrobox Power Supply

Details on powering the hydrobox via outdoor unit or independent source.

Water System Diagrams

Hydrobox Water Circuit Configurations

Diagrams showing water flow for different system setups.

Controls

Main Remote Controller Operation

Guide to using the main remote controller for system settings and monitoring.

Service Menu Functions

Access and explanation of installer/service engineer settings.

Troubleshooting

Malfunction Diagnosis and Error Codes

Procedures for identifying and resolving system errors using check codes.

Diagnosis and Action by Symptoms

Guidance on diagnosing issues based on observed phenomena and causes.

Disassembly Procedure

Component Removal and Replacement Steps

Step-by-step instructions for disassembling and reassembling unit parts.

Supplementary Information

Boiler Back-up Operation and Multi-Unit Control

Information on boiler integration and multi-unit system configurations.

Service and Maintenance

Annual Maintenance and Parts Replacement

Schedule and guidelines for routine servicing and part checks.

Engineers Forms and Settings Record

Documentation for commissioning, field settings, and maintenance logs.

Mitsubishi Electric EHSD-MED Specifications

General IconGeneral
BrandMitsubishi Electric
ModelEHSD-MED
CategoryWater System
LanguageEnglish

Related product manuals