2
FR-D700
INSTRUCTION MANUAL (Applied)
INVERTER
PRECAUTIONS FOR USE
OF THE INVERTER
PARAMETERS
TROUBLESHOOTING
PRECAUTIONS FOR
MAINTENANCE AND INSPECTION
SPECIFICATIONS
OUTLINE
WIRING
HEAD OFFICE: TOKYO BUILDING 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
MODEL
MODEL
CODE
1A2-P35
FR-D700
INSTRUCTION MANUAL (Applied)
FR-D720-0.1K to 15K
FR-D740-0.4K to 15K
FR-D720S-0.1K to 2.2K
FR-D710W-0.1K to 0.75K
IB(NA)-0600366ENG-G (1207)MEE Printed in Japan Specifications subject to change without notice.
INVERTER FR-D700 INSTRUCTION MANUAL (Applied)
G

Table of Contents

Questions and Answers:

Mitsubishi Electric FR-D720S-0.75K Specifications

General IconGeneral
ModelFR-D720S-0.75K
SeriesFR-D700
Rated Output Power0.75 kW
Horsepower1 HP
Control MethodV/f control
Protection RatingIP20
Cooling MethodFan Cooled
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheat
Weight1.5 kg

Summary

1 OUTLINE

2 WIRING

3 PRECAUTIONS FOR USE OF THE INVERTER

3.1 EMC and leakage currents

Addresses leakage currents, countermeasures, and selection of earth leakage current breakers.

3.5 Precautions for use of the inverter

General safety precautions for handling, wiring, operation, and maintenance to prevent product damage or failure.

3.6 Failsafe of the system which uses the inverter

Methods to ensure system safety by interlocking inverter status output signals and implementing backup systems.

4 PARAMETERS

4.1 Operation panel

Details on the names and functions of the operation panel components, including indicators, buttons, and display.

4.2 Parameter list

Comprehensive list of all inverter parameters, their setting ranges, initial values, and related pages.

4.3 Adjustment of the output torque (current) of the motor

Guidance on adjusting manual torque boost and magnetic flux vector control for optimal motor performance.

4.8 Selection and protection of a motor

Guidelines for selecting motors, setting overheat protection, and using offline auto tuning for optimal performance.

4.10 Function assignment of external terminal and control

Configuration of input and output terminals, communication settings, and safety stop functions.

4.12 Operation selection at power failure and instantaneous power failure

Settings for automatic restart and power-failure deceleration-to-stop functions.

4.13 Operation setting at fault occurrence

Configuration of retry functions, phase loss protection, and earth fault detection at start.

4.17 Misoperation prevention and parameter setting restriction

Functions to prevent incorrect operations, parameter rewrites, and unauthorized access.

4.18 Selection of operation mode and operation location

Configuring the inverter's operation mode (PU, External, Network) and command sources.

4.19 Communication operation and setting

Instructions for setting up communication with computers via PU connector using Mitsubishi or Modbus-RTU protocols.

5 TROUBLESHOOTING

5.1 Reset method of protective function

Steps to reset protective functions after a fault, including power OFF/ON and using the RES signal.

5.2 List of fault or alarm indications

A comprehensive list of error messages, warnings, alarms, and faults with their corresponding page references.

5.3 Causes and corrective actions

Detailed guide to diagnose and resolve common causes of error messages, warnings, and faults.

5.5 Check first when you have a trouble

Troubleshooting steps for common issues like motor not starting, abnormal noise, or incorrect speed.

6 PRECAUTIONS FOR MAINTENANCE AND INSPECTION

7 SPECIFICATIONS

7.1 Rating

Detailed specifications including applicable motor capacity, rated capacity, current, voltage, and power supply requirements.

Related product manuals