EasyManua.ls Logo

Mitsubishi Electric FR-D740-11K User Manual

Mitsubishi Electric FR-D740-11K
313 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
3
4
5
6
7
1
2
FR-D700
INSTRUCTION MANUAL (Applied)
INVERTER
PRECAUTIONS FOR USE
OF THE INVERTER
PARAMETERS
TROUBLESHOOTING
PRECAUTIONS FOR
MAINTENANCE AND INSPECTION
SPECIFICATIONS
OUTLINE
WIRING
HEAD OFFICE: TOKYO BUILDING 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
MODEL
MODEL
CODE
1A2-P35
FR-D700
INSTRUCTION MANUAL (Applied)
FR-D720-0.1K to 15K
FR-D740-0.4K to 15K
FR-D720S-0.1K to 2.2K
FR-D710W-0.1K to 0.75K
IB(NA)-0600366ENG-G (1207)MEE Printed in Japan Specifications subject to change without notice.
INVERTER FR-D700 INSTRUCTION MANUAL (Applied)
G

Table of Contents

Questions and Answers:

Mitsubishi Electric FR-D740-11K Specifications

General IconGeneral
ModelFR-D740-11K
SeriesFR-D700
Input Voltage3-phase 380-480 V AC
Power Rating11 kW
Horsepower15 HP
Cooling MethodForced air cooling
Enclosure RatingIP20
Output Voltage0-480 V
Frequency Range0-400 Hz
Control MethodV/F control
Overload Capacity150% for 60 seconds
Protection FeaturesOvercurrent, overvoltage, undervoltage, overload, short circuit, ground fault, overheating
Communication InterfacesRS-485
Operating Temperature-10 to 50 °C
Storage Temperature-20 to 65 °C
Humidity95% RH or less (non-condensing)
AltitudeUp to 1000 m
Frame SizeFR-D740

Summary

Wiring

Wiring

Diagrams and instructions for connecting power supply, motor, control circuit, and option units to the inverter terminals.

Precautions for Use of the Inverter

EMC and leakage currents

Measures to reduce electromagnetic noise, suppress harmonics, and select appropriate earth leakage current breakers.

Precautions for use of the inverter

General safety guidelines and handling precautions to prevent damage or malfunction of the inverter.

Failsafe of the system which uses the inverter

Methods to ensure system safety by providing interlocks using inverter status output signals and backup systems.

Parameters

Parameter list

A comprehensive list of all inverter parameters, their settings, initial values, and related pages for detailed explanations.

Adjustment of the output torque (current) of the motor

Methods for adjusting motor torque, including manual torque boost and slip compensation for optimal performance.

Selection and protection of a motor

Guidance on selecting appropriate motors and implementing protection measures like thermal overload and PTC thermistor protection.

Function assignment of external terminal and control

Customizing input and output terminals for various functions, including start signals, speed commands, and monitoring.

Troubleshooting

Reset method of protective function

Procedures for resetting the inverter after a fault or alarm, including power cycle and RES signal reset.

List of fault or alarm indications

A comprehensive list of error messages, warnings, alarms, and faults displayed by the inverter, with corresponding page references.

Causes and corrective actions

Troubleshooting guide for common operational faults and error messages, providing potential causes and solutions.

Check first when you have a trouble

Initial checks and common causes for issues like motor not starting, abnormal noise, or incorrect speed.