With terminal cover open
1.2 External dimensions and weight
For the input/output extension units/blocks,
refer to FX3G Series User's Manual - Hardware Edition.
Installation
35-mm-wide DIN rail or Direct (screw) mounting (M4)
2. Installation (general specifications)
As for installation of the input/output extension units/blocks, special
adapters and expansion boards, refer to the following manual.
Refer to FX3G Series User's Manual - Hardware Edition.
[8]
Operation status display LEDs
POW Green On while power is on the PLC.
RUN Green On while the PLC is running.
ERR
Red Flashing when a program error occurs.
Red Lights when a CPU error occurs.
ALM Red
Lights when the battery voltage drops.
(When the optional battery is used)
[9] Output display LEDs (red)
[10] Model name (abbreviation)
[11] DIN rail mounting hooks
No. Name
[1] Peripheral device connecting connector (USB)
[2] Peripheral device connecting connector (RS-422)
[3] RUN/STOP switch
[4]
Variable analog potentiometers
Upper side : VR1, Lower side : VR2
[5] Terminal block mounting screws
[6] Optional equipment connector1
[7] Terminal cover (FX3G-M/ES-A is excluded)
[8]
Optional equipment connector2
(40points, 60points type only)
[9] Power supply terminal, Input (X) terminals
[10] Battery connector
[11] Battery holder
[12] Power supply terminal, Output (Y) terminals
[13]
Optional equipment connecting screw holes2
(40points, 60points type only)
[14] Optional equipment connecting screw holes1
No. Name
[5]
[10]
[11]
[9]
[12]
[5]
[3]
[4]
[2]
[1]
[14] [13]
[7]
[6] [7] [8]
Model name
W:
mm (inches)
W1:
mm (inches)
Direct mounting
hole pitches
MASS (Weight)
:
kg (lbs)
FX3G-14M 90 (3.55”) 82 (3.23”) 0.50 (1.10lbs)
FX3G-24M 90 (3.55”) 82 (3.23”) 0.55 (1.21lbs)
FX
3G-40M 130 (5.12”) 122 (4.81”) 0.70 (1.54lbs)
FX3G-60M 175 (6.89”) 167 (6.58”) 0.85 (1.87lbs)
INSTALLATION
PRECAUTIONS
Use the product within the generic environment specifications
described in section 2.1 of this manual.
Never use the product in areas with excessive dust, oily smoke,
conductive dusts, corrosive gas (salt air, Cl2, H2S, SO2 or
NO
2), flammable gas, vibration or impacts, or exposed to high
temperature, condensation, or rain and wind.
If the product is used in such conditions, electric shock, fire,
malfunctions, deterioration or damage may occur.
Do not touch the conductive parts of the product directly to avoid
failure or malfunctions.
Install the product securely using a DIN rail or mounting screws.
Install the product on a flat surface.
If the mounting surface is rough, undue force will be applied to
the PC board, thereby causing nonconformities.
When drilling screw holes or wiring, make sure cutting or wire
debris does not enter the ventilation slits.
Failure to do so may cause fire, equipment failures or
malfunctions.
Be sure to remove the dust proof sheet from the PLC's
ventilation port when installation work is completed. Failure to
do so may cause fire, equipment failures or malfunctions.
W1
W
90(3.55")
82(3.23")
2-
φ
4.5 mounting holes
86(3.39")
8(0.32")
Unit: mm(inches)
Mounting hole pitches
2.1 Generic specifications
*1 The criterion is shown in IEC61131-2.
*2 Dielectric withstand voltage and insulation resistance are
shown in the following table.
For dielectric with stand voltage test and insulation resistance test of
each product, refer to the following manual.
Refer to FX
3G Series User's Manual - Hardware Edition.
*3 For common grounding, refer to section 3.3.
*4 The PLC cannot be used at a pressure higher than the
atmospheric pressure to avoid damage.
*5 Input/output extension units/blocks only
INSTALLATION
PRECAUTIONS
Connect the extension cables, peripheral device cables, input/
output cables and battery connecting cable securely to their
designated connectors.
Unsecured connection may cause malfunctions.
Turn off the power before attaching or detaching the following
devices.
Failure to do so may cause device failures or malfunctions.
- Peripheral devices, display modules, expansion boards and
special adapters
- Extension units/blocks and the FX Series terminal block
- Battery and memory cassette
Notes
When a dust proof sheet is supplied with an extension unit/
block, keep the sheet applied to the ventilation slits during
installation and wiring work.
To prevent temperature rise, do not install the PLC on a floor, a
ceiling or a vertical surface.
Install it horizontally on a wall as shown in section 2.2.
Keep a space of 50mm (1.97”) or more between the unit main
body and another device or structure (part A). Install the unit as
far away as possible from high-voltage lines, high-voltage
devices and power equipment.
WIRING
PRECAUTIONS
Cut off all phases of the power supply externally before
installation or wiring work in order to avoid damage to the
product or electric shock.
Item Specification
Ambient
temperature
0 to 55°C (32 to 131°F) when operating and -25 to
75°C (-13 to 167°F) when stored
Ambient
humidity
5 to 95%RH (no condensation) when operating
Vibration
resistance
*1
Fre-
quency
(Hz)
Accele-
ration
(m/s
2
)
Half
ampli-
tude
(mm)
Sweep Count
for X, Y, Z: 10
times
(80 min in
each
direction)
When
installed
on DIN rail
10 to 57 - 0.035
57 to 150
4.9 -
When
installed
directly
10 to 57 - 0.075
57 to 150
9.8 -
Shock
resistance
*1
147m/s
2
Acceleration, Action time: 11ms, 3 times by
half-sine pulse in each direction X, Y, and Z
Noise
resistance
By noise simulator at noise voltage of 1,000Vp-p,
noise width of 1μs, rise time of 1ns and period of 30 to
100Hz
Dielectric
withstand
voltage
*2
1.5kV AC for one
minute
Between each terminals
*2
and
ground terminal
500V AC for one
minute
Insulation
resistance
*2
5MΩ or more by
500V DC megger
Grounding
Class D grounding (grounding resistance: 100Ω or
less) <Common grounding with a heavy electrical
system is not allowed.>
*3
Working
atmosphere
Free from corrosive or flammable gas and excessive
conductive dusts
Working
altitude
<2000m
*4
Terminal
Dielectric
strength
Insulation
resistance
Main units, Input/output extension units/blocks
Between power supply
terminal (AC power) and
ground terminal
1.5 kV AC for
one minute
5MΩ or more by
500V DC megger
Between power supply
terminal (DC power) and
ground terminal
500V AC for
one minute
Between input terminal
(24V DC) and ground
terminal
500V AC for
one minute
Between input terminal
(100V AC) and ground
terminal
*5
1.5 kV AC for
one minute
Between output terminal
(relay) and ground
terminal
1.5 kV AC for
one minute
Between output terminal
(transistor) and ground
terminal
500V AC for
one minute
Between output terminal
(triac) and ground
terminal
*5
1.5 kV AC for
one minute
Expansion boards, Special function adapters, Special function
blocks
Between terminal of
expansion board and
ground terminal
Not allowed Not allowed
Between terminal of
special adapter and
ground terminal
500V AC for
1min
5MΩ or more by
500V DC megger
Special function block Each manual
Item Specification

Related product manuals