Explains the fundamental purpose and operation of the Dx-coil unit.
Details the two primary temperature control methods: RA and SA.
Illustrates practical uses of Dx-coil units in different air-conditioning scenarios.
Outlines system patterns X, Y, and Z for Lossnay and Dx-coil units.
Describes how to operate the system using different remote controllers.
Lists important technical notes and restrictions for system configuration.
Illustrates bad examples of multiple unit connections and prohibited configurations.
Details prohibited configurations for Lossnay remote controllers and TM2 connections.
Covers M-NET system prohibitions and general caution notes.
Details conditions for forced thermo-OFF, water level sensor, and drain pump operation.
Specifies the operating ranges for outdoor air, return air, and ambient conditions.
Lists compatible Lossnay and outdoor units, and refrigerant pipe size information.
Details technical specifications for GUG-01SL-E and GUG-02SL-E models.
Presents characteristic curves showing airflow drop with Dx-coil units.
Shows names of parts and overall dimensions for GUG-01SL-E.
Illustrates installation configurations for GUG-01SL-E and GUG-02SL-E with ducts.
Presents the main wiring diagram for the Dx-coil unit and connected components.
Details procedures for connecting power, remote controller, and Lossnay unit cables.
Explains how to set various functions using DIP-switches and controller settings.
Lists the default and recommended DIP-switch settings for various functions.
Identifies Lossnay functions that are restricted or unavailable when connected to Dx-coil.
Introduces the PZ-01RC controller and lists its available menu functions.
Describes the controller's display modes, interface, and physical appearance.
Details the initial setup procedures for the remote controller's functions.
Covers basic operations, error handling, and troubleshooting guidance for the controller.
Details timer settings, service options, and other controller functions.
Illustrates the refrigerant flow and key components within the system.
Provides a step-by-step flowchart for selecting appropriate units and calculating capacity.
Demonstrates cooling capacity calculation for an office floor using RA temperature control.
Demonstrates heating capacity calculation for an office floor using RA temperature control.
Guides DX-coil unit selection based on system configuration and calculation methods.
Details methods for selecting DX-coil units based on supply air temperature control.
Presents graphs for air volume factor and cooling/heating capacity performance curves.
Provides tables for capacity ratio against pipe length and air condition difference factors.