Do you have a question about the Mitsubishi Electric Mr.SLIM PE-5EAK and is the answer not in the manual?
Brand | Mitsubishi Electric |
---|---|
Model | Mr.SLIM PE-5EAK |
Category | Air Conditioner |
Language | English |
Details of the indoor unit components.
Components and operation of the remote controller.
Explains various indicators on the remote controller display.
Important notes regarding operation and indicators.
Technical specifications for indoor and outdoor units.
Information on power supply types and corresponding model names.
Electrical details like voltage, current, and power for indoor units.
Cooling capacity and correction factors for different conditions.
Correction factors based on refrigerant piping length at 50Hz.
Correction factors based on refrigerant piping length at 60Hz.
Operational data like capacity, input, and refrigerant circuit details.
Fan performance curves for PE-3EAK models.
Fan performance curves for PE-4EAK models.
Fan performance curves for PE-5EAK models.
Fan performance curves for PE-6EAK models.
Dimensional drawings and part identification for indoor units.
Dimensional drawing of the remote controller.
Wiring diagrams for indoor units and error code interpretations.
Refrigerant circuit diagrams for different models.
General troubleshooting guide based on error codes and symptom recurrence.
Method to diagnose malfunctions using the wired remote controller.
Detailed troubleshooting steps for specific error codes (P1, P2, P4, P5).
Troubleshooting for LED status and wiring issues.
Procedures for test run and emergency operation.
Procedures for checking thermistors and fan motors.
Test points on the power board.
Test points on the indoor controller board.
Explanation of dip switch and jumper wire functions.
Settings configurable via the remote controller.
Step-by-step guide for function selection.
Detailed explanation of remote controller function settings.
Overview of different system control configurations.
Operation with a single wired or wireless remote controller.
Operation with two wired or wireless remote controllers.
Collective operation of multiple refrigerant systems.
Configuration for using MA remote controller.
Settings for functions like heat pump type, auto mode, fan speed.
Checking interface status via LED lamps.
Instructions for mounting the interface unit.
How the unit recovers after a power outage.
Individual control of units from a central room.
Control from remote and local locations.
Using adapter for remote display output.
Setting timer operations for units.
Linked operation with Lossnay units.
Obtaining humidifier signal for heating operation.
External temperature sensor mounting.
Controlling units with a multiple remote display.
Interlocking operation with duct fan.
Steps for disassembling the indoor unit.
Structural parts list with RoHS compliance information.
List of electrical components with part numbers.
List of optional accessories and their part numbers.