Cooling Capacity | 9, 000 BTU/h |
---|---|
Voltage | 208 / 230 V |
Refrigerant | R410A |
Operating Temperature (Cooling) | 14°F to 115°F |
Power Supply | 208/230V, 1-Phase, 60Hz |
Outdoor Unit Dimensions (W x H x D) | 31-1/2 x 21-5/8 x 11-1/4 inches |
Operating Temperature (Heating) | 5°F to 75°F |
Noise Level (Indoor Unit) | 19 dB |
Noise Level (Outdoor Unit) | 49 dB(A) |
Heating Seasonal Performance Factor (HSPF) | 12.0 |
Lists included accessories with part numbers and quantities.
Details operational limits including voltage, temperature, and humidity.
Provides airflow, air speed, and coverage for different models and modes.
Describes how to shorten timer set times for service purposes.
Explains how to modify the P.C. board for individual unit operation with multiple remotes.
Details the auto restart feature and how to disable it.
Shows the layout and buttons of the wireless remote controller.
Explains the meaning of the operation indicator lamp on the indoor unit.
Instructions for operating the unit in COOL mode.
Instructions for operating the unit in DRY mode.
Instructions for operating the unit in HEAT mode for MSZ models.
Instructions for operating the unit in FAN mode for MSY models.
Details the "I FEEL CONTROL" operation mode for MSY models.
Explains automatic switching between COOL and HEAT modes.
Describes the operation and positioning of the auto vane feature.
Instructions for setting and releasing ON/OFF timers and program timers.
Guide to setting up and canceling the SMART SET operation mode.
How to perform emergency and test run operations on the indoor unit.
Explains the compressor protection feature against frequent starts.
How to switch between Fahrenheit and Celsius for temperature display.
Important precautions and checks before starting troubleshooting procedures.
How to recall and check past failure modes of the unit.
Table listing indoor unit failure modes, symptoms, conditions, and remedies.
A table correlating operation indicator patterns with troubleshooting steps.
Explains the meaning of operation indicator lamp patterns.
Criteria and methods for checking main parts like thermistors and motors.
Flowcharts to diagnose indoor fan motor issues.
Steps to check the remote controller and indoor electronic board functionality.
Procedures for checking the indoor P.C. board and fan motor.
Guide to identifying and correcting wiring and serial signal errors.
Steps to identify and mitigate electromagnetic interference issues.
Diagrams and voltage specifications for testing components on P.C. boards.
Disassembly procedures for specific indoor unit models.
Steps to remove the main control board and temperature sensor.
Procedures for removing the power board, terminal board, and electrical box.
Instructions for removing the air outlet nozzle assembly.
Steps to remove the vertical vane motor assembly.
Steps to remove the horizontal vane motor assembly.
Procedures for removing the fan motor, coil thermistors, and fan.
Disassembly procedures specific to the MSZ-GE24NA and MSY-GE24NA models.
Instructions for removing the air outlet nozzle assembly.
Steps to remove the vertical vane motor assembly.
Steps to remove the horizontal vane motor assembly.
Procedures for removing water cut, fan motor, thermistors, and fan.