14
22
25
22+22
22+25
25+25
Indoor units
combination
Unit A
Unit B
Cooling capacity (kW)
Total
Outdoor unit
power consumption
(kW)
Current
(A)
Power
factor
(%)
NOTE: Electrical data is for outdoor unit only.
MXZ-2A30VA
90
90
90
90
90
2.08
2.37
2.61
2.73
2.87
2.2
(0.9 - 3.0)
2.5
(0.9 - 3.3)
2.8
( 1.1 - 3.8)
2.9
(1.1 - 3.9)
3.0
(1.1 - 4.0)
0.430
(0.120 - 0.620)
0.490
(0.120 - 0.690)
0.540
(0.250 - 0.970)
0.565
(0.250 - 1.020)
0.595
(0.250 - 1.070)
1.40
1.50
1.50
2.20
2.50
1.40
1.40
1.50
INDOOR UNITS COMBINATION4
22
25
22+22
22+25
25+25
Indoor units
combination
Unit A
Unit B
Heating capacity (kW)
Total
Outdoor unit
power consumption
(kW)
Current
(A)
Power
factor
(%)
NOTE: Electrical data is for outdoor unit only.
90
90
90
90
90
3.24
3.53
3.41
3.50
3.60
3.3
(0.9 - 4.0)
3.6
(0.9 - 4.5)
3.8
(1.0 - 4.3)
3.9
(1.0 - 4.4)
4.0
(1.0 - 4.5)
0.670
(0.110 - 0.910)
0.730
(0.110 - 1.050)
0.705
(0.200 - 0.770)
0.725
( 0.200 - 0.795)
0.745
(0.200 - 0.810)
1.90
2.00
2.00
3.30
3.60
1.90
1.90
2.00