EasyManua.ls Logo

Mitsubishi Electric MXZ-3D54VA2 - User Manual

Mitsubishi Electric MXZ-3D54VA2
306 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
SERVICE MANUAL
CONTENTS
1. TECHNICAL CHANGES ··································· 2
2. PART NAMES AND FUNCTIONS ····················· 4
3. SPECIFICATION ················································ 5
4. NOISE CRITERIA CURVES ···························· 14
5. OUTLINES AND DIMENSIONS ······················ 17
6. WIRING DIAGRAM ·········································· 21
7. REFRIGERANT SYSTEM DIAGRAM ············· 50
8. PERFORMANCE CURVES ····························· 59
9. ACTUATOR CONTROL ··································· 87
10. SERVICE FUNCTIONS ···································· 88
11. TROUBLESHOOTING ····································· 92
12. DISASSEMBLY INSTRUCTIONS ·················· 121
INDOOR UNITS COMBINATION SHEETS
Models
No. OBH626
REVISED EDITION-F
HFC
utilized
R410A
SPLIT-TYPE AIR CONDITIONERS
OUTDOOR UNIT
Indoor unit service manual
MSZ-EF•VE Series (OBH589)
MSZ-SF•VA Series (OBH555)
MSZ-SF•VE Series (OBH600)
MSZ-FH•VE Series (OBH623)
MFZ-KA•VA Series (OB409)
MFZ-KJ•VE Series (OBH666)
MLZ-KA•VA Series (OBH483)
SLZ-KA•VA Series (OC320)
SEZ-KD•VA Series (HWE07110)
PLA-RP•BA Series (OCH412)
PCA-RP•KA Series (OCH454)
PEAD-RP•JA Series (HWE08130)
NOTE:
RoHS compliant products have <G> mark
on the spec name plate.
PARTS CATALOG (OBB626)
MXZ-2D33VA
MXZ-2D40VA
MXZ-2D42VA
MXZ-2D53VA MXZ-2D53VAH
Please void OBH626 REVISED EDITION-E
MXZ-2D33VA
-
E1
,
E2
,
ER2
,
ET2
MXZ-2D40VA
-
E1
,
ER2
MXZ-2D42VA
-
E2
,
ET2
MXZ-2D53VA
-
E1
,
E2
,
ER2
,
ET2
MXZ-2D53VAH
-
E1
,
E2
,
ER2
MXZ-3D54VA
-
E1
MXZ-3D54VA2
-
E2
,
ER2
,
ET2
MXZ-3D68VA
-
E1
,
E2
,
ER2
,
ET2
MXZ-4D72VA
-
E1
,
E2
,
ER2
,
ET2
MXZ-4D83VA
-
E1
,
E2
,
ER1
,
ER2
,
ET2
MXZ-5D102VA
-
E1
,
E2
,
ER1
,
ER2
,
ET2
Revision F:
MXZ-2D33/2D42/2D53/3D68/4D72/4D83/5D102VA
-
ET2
and MXZ-3D54VA2
-
ET2
have been added.

Other manuals for Mitsubishi Electric MXZ-3D54VA2

Questions and Answers

  • H
    hernandezthomasAug 8, 2025
    What to do if the Mitsubishi Electric Air Conditioner detects high pressure with the high-pressure switch (HPS) during operation?
    • D
      Donald WashingtonAug 8, 2025
      If the high-pressure switch detects high pressure during operation, check the refrigerant circuit and the refrigerant amount. Also, check the stop valve.
  • A
    Alexander JohnsonAug 14, 2025
    What should I do if the fin temperature exceeds 90 ºC during operation of my Mitsubishi Electric Air Conditioner?
    • J
      Jennifer PonceAug 14, 2025
      If the fin temperature exceeds 90 ºC during operation, check around the outdoor unit and the outdoor unit air passage.
  • E
    Emma SmithAug 20, 2025
    What to do if the discharge temperature exceeds 116 ºC during operation of Mitsubishi Electric MXZ-3D54VA2 Air Conditioner?
    • C
      Caitlin WillisAug 20, 2025
      If the discharge temperature exceeds 116 ºC during operation, check the refrigerant circuit and the refrigerant amount.
  • K
    kevinandersonAug 26, 2025
    What to do if the sensor circuit of current of compressor shorts or opens during compressor operate of Mitsubishi Electric MXZ-3D54VA2 Air Conditioner?
    • R
      Robin HartmanAug 26, 2025
      If the sensor circuit of current of compressor shorts or opens during compressor operation, replace the inverter P.C. board.
  • P
    Patrick AllenSep 1, 2025
    What to do if Mitsubishi Electric Air Conditioner nonvolatile memory data cannot be read properly?
    • G
      gaydaisySep 1, 2025
      If the nonvolatile memory data cannot be read properly, replace the inverter P.C. board.

Mitsubishi Electric MXZ-3D54VA2 Specifications

General IconGeneral
BrandMitsubishi Electric
ModelMXZ-3D54VA2
CategoryAir Conditioner
LanguageEnglish

Related product manuals